RBK (BK) series control transformers are based on the domestic BK series control transformers, further absorbed over the years
The advantages of similar products at home and abroad, the use of advanced technology and rigorous design for manufacturing, and select the foreign advanced method of wiring terminal, with excellent performance, reliable work, low energy consumption, small volume, safe wiring, wide applicability and other characteristics, is an ideal voltage power supply. The company RBK transformer won the national patent product title.It is suitable for 50-60Hz, rated power voltage not exceeding 1000V, as the control power supply for machine tools and mechanical equipment, working lighting and signal light power; also as a small power supply.
Use condition
1. The altitude shall not exceed 2000m;
2. The highest ambient temperature is + 40℃, the highest monthly average temperature is not greater than + 30℃, and the annual average temperature is not greater than + 20℃;
3. Air relative humidity is not more than 95%;
4. In ambient air, there is no harmful gas or dust that corrode metal and destroy insulation; transformers shall not be affected in use
To the erosion of water, rain and snow;
5. The power supply voltage waveform is similar to the sine wave.
Technical parameters
Type | Outlook Size(mm) | Install Size(mm) | |||
B max | D max | E max | K | J | |
RBK-50A | 85 | 80 | 92 | 65 | 60 |
RBK-100A | 103 | 90 | 110 | 75 | 64 |
RBK-150A | 103 | 98 | 110 | 75 | 74 |
RBK-200A | 103 | 105 | 110 | 75 | 77 |
RBK-250A | 114 | 122 | 125 | 90 | 90 |
RBK-300A | 114 | 127 | 125 | 90 | 95 |
RBK-400A | 132 | 130 | 142 | 94 | 97 |
RBK-500A | 132 | 135 | 142 | 94 | 102 |
RBK-700A | 150 | 140 | 175 | 127 | 115 |
RBK-1000A | 150 | 155 | 175 | 127 | 130 |
RBK-1500A | 171 | 175 | 190 | 130 | 150 |
RBK-2000A | 171 | 195 | 190 | 130 | 170 |
Note
1. Before purchasing, first estimate the total capacity of your electrical appliances, and choose them
Transformers with considerable capacity to ensure that the transformer is not burned out during instantaneous startup.
2. The transformer is designed and produced in strict accordance with the relevant national standards. When you make
When using a multi-winding (multi-control voltage) transformer, the capacity should increase the transformer capacity according to the voltage ratio, to avoid burning out the transformer.3. Before installation, carefully check the data listed in the nameplate
Your requirements, confirm the correct, can install and use.
4. After energon, the transformer core and coil will heat (but the temperature rise
Not more than 80℃) is a normal phenomenon, if the temperature rise is more than 80℃, or even smoke, it should be cut off the power switch, and re-check the capacity of your electrical appliances.
5, in the transportation, should avoid collision as far as possible, do not be affected by damp, use
Please pay attention to the maintenance to protect the service life of the transformer.