All Categories

Get in touch

epoxy resin cast dry type distribution transformer-41

Transformer

Home >  Products >  Transformer

Epoxy resin cast dry type distribution transformer

Product Description

The epoxy resin casting dry type transformer has high quality materials, scientific formula and advanced ones

Production and testing equipment is produced according to the strict process. Products have the characteristics of high reliability and long service life. Depending on the use environment, you can configure different levels of protection shell or

The shell is not configured. It can be used as a replacement product of oil-immersed transformer, suitable for high-rise buildings, commercial centers, airports, tunnels, chemical plants, nuclear power plants, ships and other important or special environmental places.

mutil_pix

Executive Standard

·GB1094.11-2007 Dry power transformer

·GB/T 10228-2008 Technical parameters and requirements for dry power transformer

·GB/T17211-1998 Load guide for dry type power transformers

·GB1094.3-2003 Power transformers third parts:insulation level,insulation test and insulation air gap

·JB/T10088-20046~500kV Transformer sound level

·JB/T 56009-1998 Classification of product quality of dry power transformer

· The international standard IEC726

Epoxy resin cast dry type distribution transformer supplier

Performance Characteristic

·Safe, fire prevention, pollution-free, can run directly in the load center.

·High mechanical strength, strong short circuit resistance, small local discharge, good thermal stability, high reliability and long service life.

· Low loss, low noise, obvious energy saving effect, maintenance free.

·Good heat dissipation performance, strong overload capacity, forced air cooling can improve the capacity of operation · Good moisture-proof performance, adapt to high humidity and other harsh environment operation.

· Can be equipped with a perfect temperature monitoring and protection system. The intelligent signal temperature control system is adopted to automatically monitor and display the working temperature of the three-phase winding on the same screen. It can automatically start and stop the fan, and set up with the functions such as alarm and trip.

· Small size, light weight, less space and low installation cost.

Technical Parameters

(KVA)RatedCapacity Voltage Marks (W)No-LoadLoss (W)120℃On-LoadLoss (W)No-LoadCur (%)Shortcirait-z (kg)HostWeight (kg)ContainShellWeight (mm)L-W-H (mm)Guage
(kV)H-V (%)Chng (kV)L-V No Protective cover Protective cover
30 66.31010.511 ±5%or±2x2.5 0.4 YynOorDyn11 165 710 2.2 4 340 435 770x500x795 1100x900x1050 350*450
50 235 1000 2.2 425 475 770x500x855 1100x900x1100 350x450
80 320 1380 1.6 525 589 1030x600x885 1350x1000x1150 550x550
100 350 1570 1.5 650 725 1090x600x900 1400x1050x1200 550x550
125 410 1850 1.4 730 820 1130x600x920 1450x1050x1200 550x550
160 475 2130 1.4 825 925 1140x710x1040 1450x1100x1250 660x660
200 545 2530 1.2 970 1085 1190x710x1060 1500x1100x1350 660x660
250 630 2760 1.2 1100 1232 1210x710x1150 1550x1100x1400 660x660
315 770 3470 1.0 1265 1458 1250x710x1305 1600x1100x1500 660x660
400 850 3990 1.0 1550 1738 1350x710x1305 1700x1150x1550 660x660
500 1015 4880 1.0 1735 1936 1380x870x1390 1700x1250x1700 820x820
630 1175 5880 0.6 2145 2340 1420x870x1480 1750x1300x1750 820x820
630 1130 5960 0.6 6 1925 2156 1470x870x1320 1800x1300x1700 820x820
800 1330 6960 0.4 2233 2530 1490x870x1460 1800x1300x1750 820x820
1000 1545 8130 0.4 2585 2915 1540x870x1560 1850x1300x1850 820x820
1250 1825 9690 0.3 3058 3410 1620x870x1680 1950x1350x1950 820x820
1600 2140 11730 0.3 3575 4005 1690x870x1730 2050x1500x2000 820*820
2000 2905 14450 0.26 4215 4742 1760x1120x1890 2050x1500*2150 1070x1070
2500 3200 17170 0.2 4785 5370 1820x1120=2010 2150x1500x2250 1070x1070